B Grade B

IonQ Oxford Ionics two-qubit prototype: Two-qubit gate fidelity

99.9916% %

As stated in the source: “estimated two-qubit gate error 8.4(7) x 10^-5 (fidelity >99.99%)”

Uncertainty: 99.9909 to 99.9923 (converted from the stated error and its uncertainty).

Caveats

Two-qubit lab prototype, not a product system. Preprint. Described as an 'estimated' error; SPAM assumed negligible. Not comparable to system-wide averages on full machines. Converted from the stated error of 8.4(7)×10⁻⁵.

Set-up
Two-qubit test setup, sequences up to N=200 Cliffords; SPAM assumed negligible (no y-offset in fit); above the Doppler limit
Method
Subspace Leakage Error Randomized Benchmarking (SLERB), 'smooth gate' without ground-state cooling
Compared only with
results in the group “single pair”
Measured
Not stated
Published
20 October 2025
Measured by
Oxford Ionics (an IonQ company)
Independent of the maker
No
Peer-reviewed
No
Repeated by others
Not yet

Source

Trapped-ion two-qubit gates with >99.99% fidelity without ground-state cooling, arXiv. Preprint. DOI: 10.48550/arXiv.2510.17286

Comparable results

Machine ValueSet-upPublishedMeasured byGradeRecord
Atom Computing Ytterbium atom array 99.4% single pair 21 May 2025 Maker B r-000037

History